ELECTRONIC TEMPERATURE INDICATOR & CONTROLLER
 
  ' CHANDRA ' DIGITAL TEMPERATURE INDICATOR   ' CHANDRA ' MULTI CHANNEL TEMPERATURE INDICATOR  
  The family of indicators accepts a variety of RTD and   This family of indicators accepts a variety of RTD and  
  Thermocouple sensor inputs and come in various DIN standard   thermocouple sensors inputs and come in various DIN standard  
  size to suit the user requirements the low power requirements   size to suit the user requirements. The low power requirements  
  of the unit, wide operating voltage and extremely low cost make   of the unit, wide operating voltage and extremely low cost  
  them ideal for a no. of applications. In additions, Dual Indicators   them ideal for a number of applications. In addition, sensors  
  which have two independant sensor inputs and individual display   sensor inputs and individual display are also avaliable in a  
  are also avaliable in a compact 96 x 96 x 110 housing.   in a compact 96 x 96 x 110 housing.  
         
  'Chandra' Digital Temperature Indicator   ' CHANDRA ' Multi Channel Temperature Indicator,  
  SPECIFICATIONS   SPECIFICATIONS  
  Input : Pt-100 / J, K Thermocouple, 4~20 mA   Input : Pt-100/J, K Thermocouple, 4~20mA  
  Display : 3½ Digit (+/-1999), 0.56"(14mm), Red LED   Display : 3½, Digit (+/-1999),0.56"(14mm), Red LED  
  Retramission : 4~20 mA / 0~1V / 0~10 V etc.   Retramission : 4~20 mA /0~1V / 0~10 V etc.  
  Supply : 230 V / 110 V AC +/- 25%   Supply : 230 V / 110 AC +/- 25%  
  Accuracy : J, K Thermocouple +/-1%,   Accuracy : J, K Thermocouple +/-1%,  
      Pt-100 -/+ 0.2% +/-1L.C.       Pt-100 -/+ 0.2% +/-1.L.C.  
                 
 
  ' CHANDRA ' Single set-Point Temperature Controller   ' CHANDRA 'Two-Set-Point Temperature Controller  
  An economical and High Reliability Design, this controller can   The controller incorporates two individual set points whose  
  be used for most of the general temperature control   logic can be preset as per the user requirements. This type of  
  applications. Adequate temperature compensation circuitry for   controller can be used in systems like Heater - Blower  
  cold junction in case of thermocouple inputs and cable length   applications, One control and one alarm Output, etc.  
  variation in case RTDs have been incorporated in this design.      
  ' CHANDRA ' Single set-Point Temperature Controller,   ' CHANDRA 'Two-Set-Point Temperature Controller,  
  SPECIFICATIONS   SPECIFICATIONS  
  Input : Pt-100 / J, K Thermocouple, 4~20mA or   Input : Pt-100 / J, K Thermocouple, 4~20mA  
    : any other input   Display : 3½, Digit (+1-1999)0.56"(14mm), Red LED  
  Display : 3½ Digit (+/-1999),0.56"(14mm), Red LED   Action(Set-1) : ON-OFF / Time Proportional / Delay  
  Action : ON-OFF / Time Proportional / Delay   Action(Set-2) : ON-OFF  
  Set Point Adj : Coarse+Fine or Single Multiturn   Hysterisis / Reset : Fixed / Variable for each Set point  
      Potentiometer.   Control : Heat / Cool / Hi-Alarm / Low-Alarm for  
  Output : 1C/O,5A/16A or 2C/O,2A resistive       individual Set Point  
  Hys./Reset : Fixed / Variable on the front Panel   Output : 1C/O, 5A / 16A or 2C/O, 2A resistive for  
  Retransmission : 4~20mA / 0~1V       each Set Point or common  
  Control : Heat / Cool / Hi-Alarm / Lo-Alarm   Set Point Adj. : Single Multi-Turn Potentiometer for each SP  
  Supply : 230V / 110V AC +/-15%   Supply : 230V / 110V AC +/-15%  
  Size : 96 x 96 x 110 mm   Size : 96 x 96 x 150 mm  
  Accuracy : J,K Thermocouple +/-1%,   Accuracy : J, K Thermocouple +/-1%,  
      Pt-100 -/+ 0.2% +/-1L.C.       Pt-100 -/+ 0.2% +/-1 L.C.  
                 
                 
 
  ' CHANDRA ' SINGLE-SET TEMPERATURE CONTROLLER (Blind)   ' CHANDRA ' DIGITAL INDICATORS  
  This family of controllers is designed for applications where   This family of general purpose indicators include ammeters,  
  cost is a constraint. This extremely rugged designed has a   Voltmeters, and other process parameters like pressure,  
  high reliability factor and comes in both ON-OFF and Time   humidity, RPM power which generate a- 4~20 mA 0~1 output.  
  Porpotional models.   Provision for retramission is also incorporated in the design.  
  ' CHANDRA ' Single-set Temperature Controller (Blind),    
  SPECIFICATIONS   SPECIFICATIONS  
  Input : PT-100 /J. K Thermocouple, 4~20 mA   Input : Current, Voltage, 4~20 mA ,0~1V  
  Control : Heat / Cool / Hi-Alarm / Lo-Alarm   Range : 100 Amps./ 1000 V or any other range.  
  Output : 1C/O, 5A / 16A resistive   Retransmission : 4~20 mA / 0~1V  
  Indification : Differential value of +/-20°C Through   Display : 3½ Digit (+/-1999), 0.56"(14mm),Red LED  
      deviation meter   Supply : 230 V / 110 VAC +/- 25%  
  Action : ON-OFF / Time Proportional   Accuracy : 0.1% +/- 2.L.C.  
  Hysterisis Reset : Fixed          
  Supply : 230 V / 110V AC +/-15%          
  Accuracy : Depending upon Range.          
 
  ' CHANDRA ' DIGITAL TIMER   ' CHANDRA ' TRANSMITTER  
  These ranges of timers include UP / DOWN counting, Battery   The JI-2W is basically a Two-Wire transmitter housed in a  
  backup features . All the timers have a state-of-the art design   sleek DIN rail mounting enclosure. The JI-4W model is housed  
  having high noise immunity and rugged circuity with minimum   in sightly larger DIN rail mounting enclosure and operates on  
  wiring and high reliability. The clock is crystal based providing   230 / 110 VAC supply. Both the transmitter accept standard  
  a high timing accuracy.   inputs like PT-100, J, K, T, etc, and converters it to a 4~20 mA  
      output. The JI-4W model does not require a 24V DC external  
      supply. The calibraion potentiometers are set to offer a wide  
      range so that the same unit can be calibrated to a wide range  
      of temperatures.  
     
  SPECIFICATIONS      
  Trigger Input : Proximity S/W or Potential free contact.   Input : Pt-100 /J, K Thermocouple, 4~20 mA, 0~1V  
  Display : 2 x 4 digit, 0.56" RED.   Operation : True Two-Wire Operation for JI-2W  
  Memory Rotention : >10 years.   Supply : 230V AC / 110 VAC +/-15% for JI - 4W  
  Supply : 230V / 110 V AC, + 10%, 50/60Hz.   Load at 20mA : 600 max. @ 24 V DC for JI-2W. 800 max  
  Count Direction : Up/Down Selectable.       For JI-4W.  
  Range : Selectable from 0.1 sec to 9999 min.   Ouptput : 4~20 mA  
  Power-on-reset : Selectable. (Battery Backup).   Range : As per user requirement.  
  Relay Logic : On/Off delay selectable.   Accuracy : J, K Thermocouple +/-1%,  
  Input Logic : Pulse/Gate trigger Logic Selectable.       Pt-100 -/+ 0.2% +/- L.C.  
  Reset Facility : Provided on front and backplate.          
  Output : Relay 1 C/O, 5A / 10A resistive          
  Size : 72 x 72 x 113 mm.          
 
  ' CHANDRA ' FLAME PROOF TEMPERATURE INSTRUMENTS   ' CHANDRA ' TEMPERATURE SENSORS  
  FLAMEPROOF ENCLOSURES FOR INDICATORS & CONTROLLERS   This wide range consist of sensors classified depending upon  
  Avaliable flameproof enclosures for Above temperature   the application, Op.Temperature, Size, Type, etc..  
  indicators and Controllers.   The range includes common types like Head - type, Pencil-  
  Indicator cum Controller ENCLOSURES CERTIFIED BY   Type, Bow-type, Handle-type Sensors Like 'L' -type sensors  
  CMRS SUITABLE FOR GAS GROUP IIA , IIB & IIC AS PER IS   specifically used for molten metal applications are also avaliable  
  2148.   The user while ordering should specify the following details:  
         
    ' CHANDRA ' Temperature Sensors.  
          Input : Pt-100, J, K, R, S, T  
          Type : Head type, Pencil -type , Leaf -type Handle  
            : type etc.  
          Temp. Range : -50°C~1700°C (depending upon the type  
              of sensors).  
          Length : 1 inch to 2 mts  
          Diameter(O.D) : 4 mm to 1 inch  
          Fitting : ½" ¾" B.S.P / N.P.T  
          Note : Refer RTD's Thermocouples, Thermocouples  
              Probes, Extruders Catalogue  
 
[Temperature Instruments] [Pressure Instruments] [Flow & Level Instruments] [Temp & Pressure Instruments Accessories] [Top]
 
Relative Links [Dial Thermometers] | [Chemical / Laboratory Glass Thermometers] | [Industrial Marine / Glass Thermometers]
  [Electronic Temperature Indicators & Controller] | [Portable Temperature Indicator / Thermohygrometers]
  [RTD'S & Thermocouples] | [Thermocouple Probes For Portable Temperature Indicator] | [Extruders]
  [Compensating Cables] | [Temperature Recorders] | [Temperature Switches] | [Temperature Indicator Crayons]
 
40, Picket Road, 2nd Floor, Kalbadevi, Mumbai - 400002, Maharashtra, India.
* Tel. : +91 (022) 22065104 / 22059501 * Telefax : +91 (022) 22065104 * Resi. : +91 (022) 28730398.
* Email : response@japsin.com / japsin33@mtnl.net.in * Website : http://www.japsin.com / http://www.japsininstrumentation.com
 

    Designed & Hosted by : MID   Promoted by : GID